500 kVA, 33/0.4 kV 50Hz Dyn11 ONAN Al Oil Immersed Transformer

  • SKU: 1601012722131
  • Category: Transformers

The 500 kVA, 33/0.4 kV 50Hz Dyn11 ONAN Al Oil Immersed Transformer is a reliable and efficient power solution for various applications. This transformer ensures safe and effective voltage transformation for your electrical systems. Built with high-quality materials, it...

R284,500

Contact Support

Asset Finance Available

Explore funding with Afrimart's partners. Subject to provider approval.

Check Funding Options
Category:
Transformers
SKU:
1601012722131
Payment security and privacy badges

Product Description

500 kVA, 33/0.4 kV 50Hz Dyn11 ONAN Al Oil Immersed Transformer

The 500 kVA, 33/0.4 kV 50Hz Dyn11 ONAN Al Oil Immersed Transformer is a reliable and efficient power solution for various applications. This transformer ensures safe and effective voltage transformation for your electrical systems. Built with high-quality materials, it provides durability and performance you can trust.

Specifications

Attribute Details
Power Rating 500 kVA
Primary Voltage 33 kV
Secondary Voltage 0.4 kV
Frequency 50 Hz
Cooling Type ONAN
Core Type Dyn11
Insulation Type Al Oil Immersed

Key Features

  • High power capacity of 500 kVA.
  • Efficient voltage transformation from 33 kV to 0.4 kV.
  • Designed for a frequency of 50 Hz.
  • Durable ONAN cooling system for effective heat dissipation.
  • Dyn11 configuration ensures stable operation.
  • Aluminum oil immersion for better insulation and performance.

Applications

  • Power distribution in industrial settings.
  • Electrical substations and feeder applications.
  • Commercial buildings requiring reliable power supply.
  • Renewable energy projects, such as solar or wind farms.
  • Data centers needing efficient voltage management.

Product Info Gallery

Product ImageProduct ImageProduct Image

Frequently Asked Questions

What are the basic electrical ratings of this transformer?

The transformer is rated 500 kVA with a primary (HV) voltage of 33 kV, secondary (LV) voltage of 0.4 kV, and designed for 50 Hz operation.

What does Dyn11 mean and why is it important?

Dyn11 is the vector group: D = delta connection on one side, y = star (wye) with neutral on the other, n = neutral available, and 11 indicates a 30° phase displacement between primary and secondary. This affects system grounding, parallel operation and protection coordination, so confirm compatibility with your network design.

What type of cooling does ONAN provide?

ONAN stands for Oil Natural Air Natural: heat is dissipated by natural convection of insulating oil inside the tank and natural air flow over the tank/radiators. It is suitable for continuous loads under normal ambient conditions without forced cooling equipment.

What does 'Al Oil Immersed' mean?

It indicates an oil-immersed transformer built using aluminum conductors/windings or aluminum components and insulated with transformer oil. Specifics (e.g., conductor material, oil type: mineral or biodegradable) should be confirmed with the manufacturer or datasheet.

What protection devices and accessories are recommended/available?

Common accessories include conservator tank with breather, oil level gauge, Buchholz relay, pressure relief valve, temperature gauges/thermostats, HV/LV bushings, surge arresters, and earthing provisions. On-request options may include on-load tap changers (OLTC), forced cooling (ONAF/ONAF+), and remote monitoring.

Can this transformer be paralleled with others?

Parallel operation is possible if transformers have the same vector group, similar percent impedance, phase shift, and compatible ratings. For Dyn11 units, ensure identical vector group and follow manufacturer guidance on impedance matching and protection coordination.

What routine tests are performed before delivery?

Typical factory tests include winding resistance, voltage ratio, no-load (excitation) test, short-circuit impedance and load loss test, insulation (power-frequency) test, and visual/functional checks. Type tests (impulse, temperature rise, noise) are available per standards on request.

What maintenance is required for an oil-immersed ONAN transformer?

Regular maintenance includes periodic visual inspections, oil level and breather checks, sampling and testing of insulating oil (DGA, moisture, acidity), monitoring temperature and cooling surfaces, checking for leaks and tightening connections. Follow the manufacturer’s maintenance schedule for frequency and specific procedures.

Are there environmental or site limitations (altitude, ambient temperature)?

Performance can be affected by high ambient temperatures and high altitude. ONAN cooling assumes moderate ambient conditions; derating may be required above specified ambient/altitude limits. Obtain manufacturer derating curves for precise guidance.

What safety and grounding measures are required during installation?

Install on a suitable foundation, use specified lifting points, provide solid earthing/grounding for tank and neutral, install surge protection, and follow lock-out/tag-out procedures during commissioning. All work should be performed by qualified personnel per local electrical codes and standards.

How long is expected service life and what warranty is typical?

Service life of a well-maintained oil-immersed power transformer is commonly several decades (20–40+ years), depending on loading, environment and maintenance. Warranty terms (duration and coverage) vary by manufacturer and should be confirmed at purchase.

What testing or checks are recommended after installation and before energization?

Perform post-installation checks: insulation resistance, ratio and polarity test, winding resistance, continuity, proper grounding, oil level and breather condition, bushing integrity, and functional checks of protective devices. Carry out a controlled energization and monitor temperatures and oil behavior.

Can the transformer handle short-term overloads?

Oil-immersed ONAN transformers can tolerate short-term overloads within manufacturer-specified limits (temperature rise and thermal capability). Exact overload capacity and permissible durations must be obtained from the manufacturer’s thermal/overload curves.

How do I obtain detailed dimensional, weight and lifting data?

Detailed mechanical drawings, weights, center-of-gravity, lifting points and foundation bolt layouts are provided by the manufacturer or in the product datasheet. Request the mechanical package before planning transport and installation.

Latest Order Arrivals

Discover our latest orders

12 Heads Embroidery Machine
12 Heads Embroidery Machine
Toilet Paper Machine  Machine
Toilet Paper Machine Machine
Order Collection
Order Collection
Cross Border Clients
Cross Border Clients
Order cros border countries  Collected
Order cros border countries Collected
Industrial Machine Cllection
Industrial Machine Cllection
Agriculture Processing Machines
Agriculture Processing Machines
Ready for collection
Ready for collection
Water Pump Equipment
Water Pump Equipment
Packaging Machine and accessories
Packaging Machine and accessories
Fabrics Manufacturing Equipment
Fabrics Manufacturing Equipment
Mining Equipments
Mining Equipments
Food Processing Machine
Food Processing Machine
Batch of Orders
Batch of Orders
Batch of Orders
Batch of Orders
Latest Orders Labelled
Latest Orders Labelled
wheel alignment machines
wheel alignment machines
new arrivals
new arrivals
Pre Orders Offloading
Pre Orders Offloading
Latest Arrivals
Latest Arrivals
Latest Arrivals
Latest Arrivals
Latest Arrivals
Latest Arrivals
Loading
Loading
Toilet paper making machine
Toilet paper making machine
Toilet paper making machine
Toilet paper making machine
Toilet paper Rewinding Machine
Toilet paper Rewinding Machine
latest arrivals
latest arrivals
offloading
offloading
order success
order success
order collection
order collection
order offloading
order offloading
collected
collected