B21, China Town Mall, Midrand
Welcome to Afrimart OnlineWrap new offers/gift every single day on Weekends.New Coupon Code: Fast024
Something you love is now on sale! Buy Now !
Diagnostic Apparatuses

portable clinical audiometer headphones medical diagnostic machine

  • SKU: 11000008283596
  • Category: Diagnostic Apparatuses

R68,000

Contact Support

Asset Finance Available

Explore funding with Afrimart's partners. Subject to provider approval.

Check Funding Options
SKU:
11000008283596
Payment security and privacy badges

Product Description

  •  

 Ad70ca8f1f1c84dfd81a4eb478875f11cK.png

Feature

Feature for portable clinical audiometer headphones medical diagnostic machine 

 

* Ideal for hearing screening work in schools, medical centers, hospitals, rehabilitation center, and enterprises etc.
* Stylish appearance design, compact and lightweight, portable and convenient,built-in battery.
* Test function: air conduction (AC), bone conduction (BC).
* With built-in microphone or external goose neck microphone (optional), easy to communicate with the tester.
* With standard USB 2.0 data interface, the audiometry data can be saved after connecting to the workstation. it can analyze and generate a professional noise diagnosis report.
* Custom report Logo and name can be set through the workstation, and A4 or B5 format report can also be generated.

A05a0b9467a2d44f89938aec7389a9d281.png

 

Specification

Specification for portable clinical audiometer headphones medical diagnostic machine 

 

 

ChannelsTwo independent output channels
Air conduction(1)Frequency: 125Hz~8000Hz;
(2)Hearing level: -10~110Db.
Bone Conduction(1)Frequency: 250Hz~6000Hz.
(2)Hearing level:-10~60dB
The allowable error of frequency±2%
Test SignalPure tone, Pulse, Warble tone, Narrow band noise
MicphoneWith built-in microphone or external goose neck microphone (optional), easy to communicate with the tester
isplay screenLCD display,Precise numerical display
Distortion factorAir conduction less than 2.5%, bone conduction less than 5.5%
MaskingAir conduction and Bone conduction Contralateral Masking
The accuracyContinuous attenuation/Step 5dB, error 1dB
Protection FunctionProtect the tester’s hearing from damage as far as possible
omputer interfaceUSB 2.0 data transmission interface, can be connected with PC for printing test report
Online Diagnosisself-analysis and generation of occupational noise-induced hearing loss diagnosis report
Operating environmentTemperature 10 ℃ ~ 40 ℃,
Relative humidity 30%~ 90%,
Pressure 86 kPa ~ 106 kPa
Warm-up time 5 to 10 minutes
Mean time between failures≥1000h
Host size325mm*195mm*27mm
Built-in batterynominal voltage 7.4V/5000mAh; continuous operation≥8 hours

 Aa57b3921d5f54603a776429fa3aea94cd.png

Main Images

    Aad5b45cbc3014a1aad4afb14f2394373e.png

 

Af336dcba06124073a6973178649de800R.png

 

Aaf48453ac3e04a2bbf69b30083333634H.png

 

A0320faf837fb42f1a2ad23c90c29d1aeH.png

 

Ab8196fc856974d32ac07795969da18d1i.png

 

 

Frequently Asked Questions

What is the primary use of the portable clinical audiometer headphones?

The portable clinical audiometer headphones are primarily used for hearing screening in various settings such as schools, medical centers, hospitals, rehabilitation centers, and enterprises.

Is the audiometer portable?

Yes, the audiometer is designed to be compact and lightweight, making it easy to transport and use in different locations.

What types of hearing tests can this audiometer perform?

The audiometer can perform air conduction (AC) and bone conduction (BC) hearing tests.

Does the audiometer come with a built-in microphone?

Yes, the audiometer features a built-in microphone, and there is also an option for an external goose neck microphone for easier communication.

How can I save the audiometry data?

The audiometer has a standard USB 2.0 data interface that allows you to connect it to a workstation, where you can save and analyze the audiometry data.

Can I customize the test reports?

Yes, you can customize the reports by setting a logo and name through the workstation, and generate reports in A4 or B5 format.

What frequencies does the audiometer test for air conduction?

For air conduction, the audiometer tests frequencies ranging from 125Hz to 8000Hz.

What is the allowable error for frequency testing?

The allowable error for frequency testing is ±2%.

What is the distortion factor for air and bone conduction?

The distortion factor is less than 2.5% for air conduction and less than 5.5% for bone conduction.

What are the operating environmental conditions for the audiometer?

The audiometer operates optimally in temperatures ranging from 10°C to 40°C, with a relative humidity of 30% to 90%.

How long can the built-in battery last on a single charge?

The built-in battery has a nominal voltage of 7.4V/5000mAh and can provide continuous operation for up to 8 hours.

What is the warm-up time for the audiometer?

The warm-up time for the audiometer is between 5 to 10 minutes.

What test signals can the audiometer generate?

The audiometer can generate pure tone, pulse, warble tone, and narrow band noise test signals.

How does the audiometer protect the tester's hearing?

The audiometer is designed with protection functions to help prevent damage to the tester's hearing during use.

What is the mean time between failures for this device?

The mean time between failures for the audiometer is greater than or equal to 1000 hours.

Latest Order Arrivals

Discover our latest orders

12 Heads Embroidery Machine
12 Heads Embroidery Machine
Toilet Paper Machine  Machine
Toilet Paper Machine Machine
Order Collection
Order Collection
Cross Border Clients
Cross Border Clients
Order cros border countries  Collected
Order cros border countries Collected
Industrial Machine Cllection
Industrial Machine Cllection
Agriculture Processing Machines
Agriculture Processing Machines
Ready for collection
Ready for collection
Water Pump Equipment
Water Pump Equipment
Packaging Machine and accessories
Packaging Machine and accessories
Fabrics Manufacturing Equipment
Fabrics Manufacturing Equipment
Mining Equipments
Mining Equipments
Food Processing Machine
Food Processing Machine
Batch of Orders
Batch of Orders
Batch of Orders
Batch of Orders
Latest Orders Labelled
Latest Orders Labelled
wheel alignment machines
wheel alignment machines
new arrivals
new arrivals
Pre Orders Offloading
Pre Orders Offloading
Latest Arrivals
Latest Arrivals
Latest Arrivals
Latest Arrivals
Latest Arrivals
Latest Arrivals
Loading
Loading
Toilet paper making machine
Toilet paper making machine
Toilet paper making machine
Toilet paper making machine
Toilet paper Rewinding Machine
Toilet paper Rewinding Machine
latest arrivals
latest arrivals
offloading
offloading
order success
order success
order collection
order collection
order offloading
order offloading
collected
collected