Medical hospital arthroscopy instrument set arthroscopy camera equipment arthroscopy tower

  • SKU: 1600242206355
  • Category: Medical Ultrasound Instruments

The DJ DJSXJ-IIa Surgical Camera is a high-performance Class II medical imaging device, designed to deliver exceptional clarity for surgical procedures. With advanced imaging technology and user-friendly features, this camera is ideal for minimally invasive surgery, dia...

R69,429

Contact Support

Asset Finance Available

Explore funding with Afrimart's partners. Subject to provider approval.

Check Funding Options
SKU:
1600242206355
Payment security and privacy badges

Product Description

DJ DJSXJ-IIa Surgical Camera System

The DJ DJSXJ-IIa Surgical Camera is a high-performance Class II medical imaging device, designed to deliver exceptional clarity for surgical procedures. With advanced imaging technology and user-friendly features, this camera is ideal for minimally invasive surgery, diagnostic imaging, and other medical applications requiring precision and reliability.

Key Features and Benefits:

  • High-Resolution Imaging: Equipped with a Sony IMX185 CMOS Sensor, this camera offers 1920 x 1080 effective pixels and a 1000 TVL resolution, ensuring sharp and clear visuals for accurate diagnostics.
  • Advanced Photometry: Features average, peak, and area photometry to enhance image quality and lighting control, enabling precise visual information during surgical procedures.
  • Flexible Exposure Control: The camera offers auto/manual exposure options and an auto shutter range of 1/50 to 1/4000, allowing for easy adjustment to different lighting conditions.
  • Wide Illumination Range: With an illumination reference of 3000K-8000K, the system provides optimal lighting for detailed imaging.
  • Waterproof Design: The camera head has an IPX7 waterproof rating, making it safe for use in surgical environments where sterilization is essential.
  • C-Mount Lens: Compatible with C-mount lenses, providing flexibility in lens selection for various imaging needs.

Specifications:

  • Model Number: DJSXJ-IIa
  • Instrument Classification: Class II
  • Safety Standard: None
  • Place of Origin: Hunan, China
  • Brand Name: DJ
  • Power Source: Electric
  • Material: Metal, Plastic, Glass, PCBA, PVC
  • Shelf Life: 2 Years
  • Quality Certification: TUV
  • Image Sensor: 1/1.9" Sony IMX185 CMOS Sensor
  • Unit Cell Size: 3.7μm x 3.7μm
  • Effective Pixels: 1920(H) x 1080(V)
  • Resolution: 1000 TVL
  • Photometry: Average, Peak, and Area Photometry
  • Exposure: Auto/Manual
  • Shutter: Auto range 1/50 - 1/4000
  • Illumination Reference: 3000K-8000K
  • Waterproof: Camera Head IPX7 Waterproof
  • Lens Mount: C-Mount

Product Info Gallery:

  • High-Resolution Imaging: Ensure sharp, clear visuals for all surgical procedures with 1000 TVL resolution.
  • Waterproof and Durable: The camera is built for reliability in challenging environments with an IPX7 waterproof rating.
  • Advanced Features: Auto and manual exposure adjustments, along with flexible photometry settings, allow for optimal imaging in various lighting conditions.

Enhance Your Surgical Precision

The DJ DJSXJ-IIa Surgical Camera offers excellent imaging capabilities, ensuring you can capture precise, high-quality visuals for every procedure. Its robust design, flexible settings, and waterproof feature make it a dependable tool for any surgical or medical setting.

Order the DJ DJSXJ-IIa Surgical Camera today to experience superior imaging technology for your medical practice!

Image Sensor1I1,9"Sony IMX185 CMOS Sensor
Unit Cell Size3.7s um x 3.Ts um
Effective Pixels1920(H) X 1080 (V)
Resolution1000 TVL
photometyAverage. peak and area photomety
ExposureAuto/Manual
lmage Gamma0.45, 0.55. 0.65, 0.75
shutterAuto r8nge 1/5O - 1/4000
Lens MountC-Mount
Scanning ModeProgressive
IlIumination Ref3000K-8000K
Min.Sensitivity 20Lx F1,4
WaterproofCamera head IPX7 waterproof

He8483b453f2c46319e2312caaac65f41H.jpg

Ha020ad29036f4828b91efa4d8b1b445bR.jpg

H397e351929424daa923b647e50f00ddeB.jpg

Frequently Asked Questions

What is the DJ DJSXJ-IIa Surgical Camera and what procedures is it intended for?

The DJ DJSXJ-IIa is a Class IIS surgical camera system designed for high-resolution imaging in minimally invasive surgery, arthroscopy, diagnostic imaging and other surgical applications that require precise visualisation.

What are the key imaging specifications (sensor, resolution, pixels)?

The camera uses a 1/1.9" Sony IMX185 CMOS sensor with a unit cell size of 3.7 μm × 3.7 μm, effective pixels of 1920 (H) × 1080 (V) and a quoted resolution of 1000 TVL.

What does '1000 TVL' mean compared with 1920×1080 pixels?

1920×1080 describes the digital pixel count (Full HD). TVL (TV lines) is an analog-style measure of horizontal detail resolution; a 1000 TVL rating indicates very high horizontal detail performance. Both metrics together indicate the camera delivers high-definition digital imaging with strong analog-style detail.

What photometry and exposure controls does the camera provide?

The system supports average, peak and area photometry modes and offers both auto and manual exposure control. The electronic shutter range is adjustable from 1/50 to 1/4000 to adapt to different lighting conditions.

What are the illumination and sensitivity characteristics?

The illumination reference (color temperature) covers approximately 3000K–8000K to match different light sources. Minimum sensitivity is specified as 20 lx at F1.4, making it suitable for well-lit endoscopic/arthroscopic procedures.

Is the camera head waterproof and can it be sterilised?

The camera head has an IPX7 waterproof rating (protection against temporary immersion up to 1 m for 30 minutes). This makes it resistant to fluids encountered in OR settings; however, for approved sterilisation and cleaning methods (eg. high-temperature autoclave, chemical sterilants, low‑temperature systems) follow the manufacturer's specific cleaning and sterilisation instructions and your hospital's infection control protocols.

What lens and optics options are supported?

The camera uses a standard C-mount lens interface, allowing use of C-mount lenses and endoscopic couplers compatible with C-mount. Choose lenses/couplers that match your endoscope and desired field of view; consult your supplier for recommended lens models.

How does the camera integrate with arthroscopy towers and video systems?

Integration depends on the tower/capture system interfaces. The DJSXJ-IIa provides a C-mount optical interface; video/data output and cable types vary by tower. Contact the tower manufacturer or DJ supplier to confirm required video interfaces, capture cards, and connector/cable options for your system.

What are the physical materials, power source and product origin?

The unit is constructed from metal, plastic, glass, PCBA and PVC components. The camera system is electrically powered. The product origin is Hunan, China.

What certifications and regulatory classification does this camera have?

The camera is classified as Class IIS (surgical) and carries TUV quality certification. The product listing shows no additional safety standard specified; verify local regulatory requirements for clinical use in your region before deployment.

What is the expected shelf life and recommended storage?

The product listing indicates a shelf life of 2 years. For storage, keep the unit in its original packaging in a clean, dry environment at temperatures and humidity levels recommended by the manufacturer—contact DJ for specific storage temperature and humidity ranges.

What image settings and scan mode are available?

The camera supports progressive scanning and selectable image gamma settings (0.45, 0.55, 0.65, 0.75). These settings let you tailor contrast and brightness for optimal surgical imaging.

What should I do if I experience image quality problems (noise, blur, colour issues)?

Check focus and C-mount lens seating, confirm illumination source and colour temperature, verify exposure and gamma settings, and inspect the endoscope optics and cable connections. If problems persist, contact your equipment supplier or DJ technical support for troubleshooting and service recommendations.

Latest Order Arrivals

Discover our latest orders

12 Heads Embroidery Machine
12 Heads Embroidery Machine
Toilet Paper Machine  Machine
Toilet Paper Machine Machine
Order Collection
Order Collection
Cross Border Clients
Cross Border Clients
Order cros border countries  Collected
Order cros border countries Collected
Industrial Machine Cllection
Industrial Machine Cllection
Agriculture Processing Machines
Agriculture Processing Machines
Ready for collection
Ready for collection
Water Pump Equipment
Water Pump Equipment
Packaging Machine and accessories
Packaging Machine and accessories
Fabrics Manufacturing Equipment
Fabrics Manufacturing Equipment
Mining Equipments
Mining Equipments
Food Processing Machine
Food Processing Machine
Batch of Orders
Batch of Orders
Batch of Orders
Batch of Orders
Latest Orders Labelled
Latest Orders Labelled
wheel alignment machines
wheel alignment machines
new arrivals
new arrivals
Pre Orders Offloading
Pre Orders Offloading
Latest Arrivals
Latest Arrivals
Latest Arrivals
Latest Arrivals
Latest Arrivals
Latest Arrivals
Loading
Loading
Toilet paper making machine
Toilet paper making machine
Toilet paper making machine
Toilet paper making machine
Toilet paper Rewinding Machine
Toilet paper Rewinding Machine
latest arrivals
latest arrivals
offloading
offloading
order success
order success
order collection
order collection
order offloading
order offloading
collected
collected