π Important:
All orders, emails, and quotations will be processed and responded to once we reopen on 3rd January 2025.
Thank you for your understanding and patience!
π Festive Closing Notice:
We will be closed from 21st December 2024 to 3rd January 2025.
Wishing you a joyous holiday season! π
Cardiopulmonary Resuscitation Simulator This product uses the 2015 Cardiopulmonary Resuscitation operating standard, and its core modules include Simulator and Cardiopulmonary Resuscitation Display. Cardiopulmonary resuscitation training and assessment, printing and display integration. Applicable to social cardiopulmonary resuscitation training institutions, hospitals, medical schools, health schools, Red Cross and other units for cardiopulmonary resuscitation training.Technical Parameters:1. When the artificial hand is pressed outside the chest:
(1) the bar code indicator dynamically displays the pressing strength,
(2) the digital counting display, and
(3) the language prompt;2. When the artificial mouth is breathing (blowing):
(1) the bar code indicator dynamically displays the tidal volume,
(2) the digital count display, and (2) the language prompt;3. Pressing and artificial breathing ratio: 30:2 (single or double);4. Cardiopulmonary resuscitation simulated human operation cycle: 2 effective artificial insufflation, and then press and manual insufflation 30:2 five cycle cycle CPR operation;5. Cardiopulmonary resuscitation simulated human operating frequency: the latest 2015 international standard: at least 100~120 beats/min;6. Cardiopulmonary resuscitation simulated human operation mode: training operation, universal assessment, professional assessment;7. Cardiopulmonary resuscitation simulated human operation time: timed in seconds;8.
Controller display function requirements:(1) Electronic monitoring: The electronic indicator light shows the monitoring of the open and pressed parts of the airway. The number of correct counts and number of errors for artificial respiration and chest compressions;(2) Language prompt: Chinese voice prompts in the whole process of training and assessment, which can switch the voice and adjust the volume;(3) Barcode shows the amount of air blown (correctly 500~600ml-1000ml): when the blow volume is too small, the barcode is yellow; when the blow volume is appropriate, the barcode is green; when the blow volume is too large, the barcode is red; the tidal volume is blown Fast or oversized, causing gas to enter the stomach indicator light. Digital counting display, incorrect language prompts;(4) The bar code displays the pressing depth (correctly 5-6cm): when the pressing depth is too small, the bar code is yellow; when the pressing depth is appropriate, the bar code is green; when the pressing depth is too large, the bar code is red;9. Check the pupil reaction: the actual embodiment of the automatic dynamic change process of the simulated pupil before and after the operation is completed;10. Check the carotid artery reaction: touch the test by hand to simulate the auto-beating reaction of the carotid artery during the pressing operation; and the true expression of the auto-beating reaction of the carotid artery after the operation of the assessment procedure is completed;11. Grade printing: The printing operation process after the operation ends. The transcript contains the operation mode, consciousness judgment, emergency breathing, pulse check, check breathing, foreign matter removal, operating frequency, pressing and blowing ratio, number of cycles, number of pressing and blowing in each cycle operation, pressing correct/error The number of times, the cause and number of pressing errors, the reason and number of blowing errors/errors, the cause of blowing errors, setting time, operating time, and assessment;12. Cardiopulmonary resuscitation simulation power supply: 220V power supply, 12V output power supply after voltage regulator regulation. (Optional with lithium battery, suitable for direct use without external power supply); Standard set configuration:(1) a high-level resuscitation whole body model;(2) One advanced display controller;(3) One of the luxury hand-push type human body plastic boxes;(4) a recovery operation pad;(5) one power adapter;(6) One data line;(7) A box of CPR disinfection mask (50 sheets/box);(8) Four sets of replaceable lung capsule devices;(9) One face can be changed;(10) two volumes of thermal printing paper;(11) 2015 International Operation Guide CD 1;(12) 1 manual of common technical use for on-site first aid;(13) a manual;(14) Warranty card, certificate of conformity.
Specification
item
value
Place of Origin
China
Guangdong
Brand Name
Happycare
Model Number
HC-S019
Product name
cpr manikin
Material
silicone
Function
School teaching
Warranty
1 year
MOQ
1set
Size
1:1 human size
Packaging
Carton Case
Weight
30kg
Shipping Timeframes: All orders are processed within 2-5 business days (excluding weekends and holidays). After your order has been processed, the estimated delivery time is before 20 Feb, 2025, depending on customs, Please note that due to high demand, some items may experience longer shipping times, which will be communicated at order confirmation email.
Order Processing Time: Please allow 2-5 business days for us to process your order before it is shipped . Orders placed after 16:00 on Fridays, or during weekends and public holidays, will begin processing on the next business day. Processing times may be extended during peak seasons or sales events.
Manufacturing Time: Some products needs manufacturing time, the manufacturing process will take approximately 10-30 business days depending on the product. This timeframe may vary depending on the complexity of the product and current demand. but this will be communicated with you during order confirmation.
Returns and Exchanges: We offer a 30-day return policy for most items. If you are not completely satisfied with your purchase, you may return it within 30 days of receipt for a refund or exchange. Items must be unused, in their original packaging, and accompanied by proof of purchase. Return shipping costs are the responsibility of the customer, unless the item was damaged or defective upon arrival.
0
0 Overall Rating
5
0%
0
4
0%
0
3
0%
0
2
0%
0
1
0%
0
Review this product
For you to write a review, you need to login first
Afrimart Online stands as Africa's foremost e-commerce hub, featuring an expansive array of product categories spanning electronics, machinery, toys, furniture, and more. Committed to excellence, our platform delivers swift and streamlined logistics and customs clearance solutions, offering a comprehensive one-stop service for cross-border imports.
Leveraging over three decades of international trade expertise, we ensure a seamless and hassle-free importing experience, providing top-tier products at competitive prices to meet the diverse needs of African consumers.
At Afrimart, we strive to process all orders promptly. Once the payment has been successfully cleared into our account, your order will be processed within 2 to 5 business days. Please note that this processing time excludes weekends and public holidays.
Following the processing of your order, the estimated delivery lead time ranges between 35 to 60 days. However, please be aware that this timeframe is subject to variations due to potential delays in shipping and customs clearance. While we aim to adhere to the original delivery schedule, unforeseen circumstances may occasionally extend the delivery window beyond the anticipated 35 to 60 days.
In the event of high demand or other factors leading to longer shipping times for certain items, we will communicate any expected delays during the initial order confirmation. We appreciate your understanding and patience as we work to ensure your order arrives as swiftly as possible.