- Deposit amount:
R23,476
- Future payments:
R15,650
- Estimated delivery:
on 29 June 2024 - 29 July 2024
-
- Deposit amount:
R2,399
- Future payments:
R1,600
- Estimated delivery:
on 29 June 2024 - 29 July 2024
-
- Deposit amount:
R2,639
- Future payments:
R1,760
- Estimated delivery:
on 29 June 2024 - 29 July 2024
-
- Deposit amount:
R227,054
- Future payments:
R151,370
- Estimated delivery:
on 29 June 2024 - 29 July 2024
-
- Deposit amount:
R189,018
- Future payments:
R126,012
- Estimated delivery:
on 29 June 2024 - 29 July 2024
-
- Deposit amount:
R1,319
- Future payments:
R880
- Estimated delivery:
on 29 June 2024 - 29 July 2024
-
- Deposit amount:
R97,679
- Future payments:
R65,119
- Estimated delivery:
on 29 June 2024 - 29 July 2024
-
- Deposit amount:
R4,377
- Future payments:
R2,918
- Estimated delivery:
on 29 June 2024 - 29 July 2024
-
- Deposit amount:
R203,280
- Future payments:
R135,520
- Estimated delivery:
on 29 June 2024 - 29 July 2024
-
- Deposit amount:
R4,199
- Future payments:
R2,800
- Estimated delivery:
on 29 June 2024 - 29 July 2024
-
- Deposit amount:
R134,854
- Future payments:
R89,902
- Estimated delivery:
on 29 June 2024 - 29 July 2024
-
- Deposit amount:
R1,799
- Future payments:
R1,200
- Estimated delivery:
on 29 June 2024 - 29 July 2024
-
- Deposit amount:
R14,399
- Future payments:
R9,600
- Estimated delivery:
on 29 June 2024 - 29 July 2024
-
- Deposit amount:
R7,348
- Future payments:
R4,898
- Estimated delivery:
on 29 June 2024 - 29 July 2024
Roll over image to zoom in
Factory high end 3 phases 5pcs 30kw modules Modular 150kw 150kva ups for server rooms
R335,412 Excl VAT
Pay over 3 EQUAL zero-interest
instalments of R111,804 with PayJustNow.
Find out how...
PayJustNow is a simple, easy-to-use payment system.
Here’s how it works:
PayJustNow allows you to pay for your purchase over 3 equal, zero interest instalments. You’ll pay one instalment at the time of purchase, the next at the beginning of the following month and the last one a month thereafter.
#zerointerest
Step 1:
Browse your favourite online stores and proceed to check-out.
Step 2:
Choose PayJustNow as your payment method.
Step 3:
Create your account as easily as if your eyes were shut (though we’d recommend you keep them open).
Step 4:
Complete your purchase and whoop for joy!
Here’s what you’ll need:
A valid RSA ID document
To be over 18 years old
An email address
A SA Bank issued debit or credit card
ECOplus 30-300kVA Modular UPS (30k module)
Introduction:
ECOplus 30-300kVA is a modular design UPS. It uses on-line double conversion and advanced DSP digital control technology, resulting in the highest levels of reliability. The UPS is three phase in, three phase out, with each module is 30kVA. It’s available from 30kVA to 300kVA unit capacity, and parallel 4 units to 1200kVA.
Scenarios:
Medium data centers, server rooms
Telecom, IT equipment, group enterprises,
and other mission-critical applications
Features:
1.Centralized bypass, centralized control, modular design
2.Online double conversion and three level technology
3.DSPÂ digital control technology
4.Wide input voltage range
5.Output power factor 1
6.High power density with size 440mm*620mm*2U
7.Cold start (battery start up)
8.ECOÂ mode operation
9.Intelligent battery management
10.N X redundancy
11.Communications:Â RS485/Relay card/USB/SNMPÂ option
12.Optional emergency power off (EPO) function
13.Compatible with lithium battery applications
Benefits:
1.Modular design, improves maintainability and reliability
2.ECOÂ mode operation for energy saving
3.Cold start for easy operation
4.Communications for network management and remote monitoring
5.N X redundancy, expanding as required, saves initial investment
30k specifications
Model | ECOplus90-30 | ECOplus150-30 | ECOplus300-30 | ||
Capacity | UPS Cabinet | 30~90kVA | 30~150kVA | 30~300kVA | |
UPS Module | 30kVA | ||||
3 | 5 | 10 | |||
Input | Phase | 3 Phase 4 Wires and Ground | |||
Rated Voltage | 380/400/415Vac | ||||
Voltage Range | 138~485Vac | ||||
Frequency Range | 40Hz-70Hz | ||||
Power Factor | ≥0.99 | ||||
Current THDi | ≤3%(100% linear load) | ||||
Bypass Voltage Range | Max.voltage: 220V: 25 %( optional 10%, 15%, 20%); 230V: 20 %( optional 10%, 15%);Â Â 240V: 15 %( optional 10%);Min. voltage: -45% (optional -20%,-30%) | ||||
Frequency protection range: ±10% | |||||
Power Walking In | Yes | ||||
Bypass back irrigation | Bypass back irrigation | ||||
Generator access | Yes | ||||
Output | Phase | 3 Phase 4 Wires and Ground | |||
Rated Voltage | 380/400/415Vac | ||||
Power Factor | 1 | ||||
Voltage Regulation | ±1% | ||||
Frequency | Utility Mode | ±1%,±2%,±4%,±5%,±10% of the rated frequency(optional) | |||
Battery Mode | (50/60±0.1%)Hz | ||||
Crest Factor | 3:1 | ||||
THD | ≤2% with linear load, ≤5% with non linear load | ||||
Efficiency | 96% | ||||
Overload | ≤ 110%, to bypass after 60min; ≤ 125%,to bypass after 10min; ≤ 150%,to bypass after 1min | ||||
Battery | Voltage | ±180V/192V/±204V/±216V/±228V/±240/±252/±264/±276/±288/±300Vdc(30/32/34/36/38/40/42/44/46/48/50pcs optional) | |||
Charging Current | UPS Cabinet | 30A Max. | 50A Max. | 100A Max. | |
UPS Module | 10A Max. | ||||
Transfer Time | Utility to Battery : 0ms; Utility to bypass: 0ms | ||||
Protection | Alarm | overload, utility abnormal, UPS fault, battery low, etc | |||
Protection | short circuit, overload, over temperature, battery low, fan fault alarm | ||||
Communication Interface | RS232, RS485, Intelligent slot x 2, Dry Contact,SNMP | ||||
Environment | Operating Temperature | 0℃~40℃ | |||
Storage Temperature | -25℃~55℃ | ||||
Humidity | 0~95% non condensing | ||||
Altitude | < 1500m | ||||
Other | Unit Dimensions(D*W*H) | UPS Cabinet | 850x600x1350mm | 850x600x1350mm | 850x600x2000mm |
UPS Module | 620x440x86mm | ||||
Weight (Kg) | UPS Cabinet | 160 | 170 | 275 | |
UPS Module | 21 | ||||
Standards | EN62040-1, EN62040-2 |
Pictures