B21, China Town Mall, Midrand
Welcome to Afrimart OnlineWrap new offers/gift every single day on Weekends.New Coupon Code: Fast024
Something you love is now on sale! Buy Now !
Portable Handheld 3 Channel ECG Electrocardiograph with Thermal Printer for Hospital

0 Customer Reviews

  • Shipping Timeframes: All orders are processed within 2-5 business days (excluding weekends and holidays). After your order has been processed, the estimated delivery time is before 03 Feb, 2026, depending on customs, Please note that due to high demand, some items may experience longer shipping times, which will be communicated at order confirmation email.
  • Order Processing Time: Please allow 2-5 business days for us to process your order before it is shipped . Orders placed after 16:00 on Fridays, or during weekends and public holidays, will begin processing on the next business day. Processing times may be extended during peak seasons or sales events.
  • Manufacturing Time: Some products needs manufacturing time, the manufacturing process will take approximately 10-30 business days depending on the product. This timeframe may vary depending on the complexity of the product and current demand. but this will be communicated with you during order confirmation.
  • Returns and Exchanges: We offer a 30-day return policy for most items. If you are not completely satisfied with your purchase, you may return it within 30 days of receipt for a refund or exchange. Items must be unused, in their original packaging, and accompanied by proof of purchase. Return shipping costs are the responsibility of the customer, unless the item was damaged or defective upon arrival.
1. What is the main function of the Portable Handheld 3 Channel ECG Electrocardiograph?

The main function of the Portable Handheld 3 Channel ECG Electrocardiograph is to monitor and record the electrical activity of the heart, providing crucial data for diagnosing heart conditions.

2. What is the resolution and frequency response of this ECG device?

The ECG device has a resolution of 12-bit at a sampling rate of 1000Hz and a frequency response ranging from 0.05Hz to 150Hz.

3. How does the built-in thermal printer work?

The built-in high-resolution thermal printer allows for immediate printing of ECG results on thermal recording paper, with adjustable paper speeds of 12.5, 25, and 50 mm/s.

4. Can this ECG device operate in both manual and automatic modes?

Yes, the Portable Handheld 3 Channel ECG Electrocardiograph can operate in both manual and automatic modes, providing flexibility for different user preferences.

5. What is the input impedance of this ECG device?

The input impedance of this ECG device is greater than 50MΩ, ensuring minimal interference from external electrical sources.

6. What type of battery does this device use and what is its capacity?

This ECG device is powered by a built-in rechargeable Li-ion battery with a voltage of 11.1V and a capacity of 2200mAh.

7. Is there a risk of patient current leakage with this device?

The device is designed with safety in mind, featuring a patient current leakage of less than 10µA, which minimizes any risk to patients.

8. What is the drift filter feature in this ECG device?

The drift filter feature, also known as the Anti-Drift System, helps to eliminate baseline drift in ECG readings, ensuring more accurate results.

9. What are the dimensions of the device packaging?

The dimensions of the packaging for the Portable Handheld 3 Channel ECG Electrocardiograph are 256mm x 204mm x 66mm.

10. What is the noise level specification for this ECG device?

The noise level for this ECG device is ≤ 15µVp-p, which helps to ensure clear and accurate readings.

11. What type of filters does this ECG device have?

The device includes an AC filter and an EMG filter to reduce interference from electrical noise and muscle activity.

12. How is the calibration voltage specified for this device?

The calibration voltage for this ECG device is set at 1mV ± 3%, ensuring accuracy in the readings.

13. What are the available sensitivity settings for this ECG device?

The ECG device offers sensitivity settings of 5, 10, and 20 mm/mV, allowing users to adjust the output based on patient needs.

14. What type of recording paper is compatible with this ECG device?

The device uses thermal recording paper specifically designed for high-resolution printing of ECG results.

15. What is the CMRR specification for this device?

The Common Mode Rejection Ratio (CMRR) for this ECG device is ≥ 100dB, which helps to improve the accuracy of the ECG readings by rejecting noise.

0

0 Overall Rating
  • 5
    0%
    0
  • 4
    0%
    0
  • 3
    0%
    0
  • 2
    0%
    0
  • 1
    0%
    0

Review this product

For you to write a review, you need to login first

Login

Latest Order Arrivals

Discover our latest orders

12 Heads Embroidery Machine
12 Heads Embroidery Machine
Dewatering Pump Machine
Dewatering Pump Machine
Order Collection
Order Collection
Portable Water Drilling Rig
Portable Water Drilling Rig
Order Usefully Collected
Order Usefully Collected
Batch of Orders
Batch of Orders
Agriculture Processing Machines
Agriculture Processing Machines
Meat Grinder Machine
Meat Grinder Machine
Water Pump Equipment
Water Pump Equipment
Packaging Machine and accessories
Packaging Machine and accessories
Fabrics Manufacturing Equipment
Fabrics Manufacturing Equipment
Mining Equipments
Mining Equipments
Food Processing Machine
Food Processing Machine
Batch of Orders
Batch of Orders
Batch of Orders
Batch of Orders
Latest Orders Labelled
Latest Orders Labelled
wheel alignment machines
wheel alignment machines
new arrivals
new arrivals
Pre Orders Offloading
Pre Orders Offloading
Latest Arrivals
Latest Arrivals
Latest Arrivals
Latest Arrivals
Latest Arrivals
Latest Arrivals

Related Products

Recently Viewed Products