Building Boards & Insulation
Coated & Treated Products
Decorative Building Materials
EPDM/PVC/TPO Membrane
Flat Products (Sheets, Plates & Coils)
Gabion mesh
Geocell
Geogrid
Geomembrane Welding machine
HDPE Geomembrane
HDPE Geomembrane
Hdpe/Pvc Pipe
Industrial Hardware & Fasteners
LDPE LLDPE Geomembrane
Luxury Wall Panels
Nonwoven Geotextile
Other Geosynthetics
Pipe Floater
Pipeline & Fluid Systems
Pipes & Hollow Sections
PVC Ceilings
PVC Cornices
PVC Suspended Ceilings
PVC Wall Panels
Roofing & Cladding
Roofing & Corrugated Sheets
Rubber Hose
SPC Flooring
Strips & Bars
Structural Steel & Profiles
Camera & Photo
Chargers, Batteries & Power Supplies
Commercial Equipment
Home Audio & Video
Portable Audio
Printing Equipment
Professional Audio
Security & Protection
Testing Equipment
Advertising Boards
Advertising Inflatables
Advertising Light Boxes
Commercial Fryers
Computer Hardware & Software
Digital Signage and Displays
Display Racks
Food Trucks
Ice Cream Machines
Interactive Boards
Photo Booths
Projectors & Presentation Equipments
Refrigeration Equipment
Supermarket Shelves
Vending Machines
Bedroom Furniture
Commercial Furniture
Decorations
Dining Room Furniture
Kitchen Furniture
Living Room Furniture
Office Furniture
Agriculture Machinery
Apparel Machinery
Chemical Machinery
Cleaning Equipment
Construction Machinery
Environmental Machinery
Food & Beverage Machinery
Industrial Machinery
Machine Tool Equipment
Machinery Accessories
Material Handling
Packaging Machines
Brick Making Machinery
Concrete Mixers
Concrete Pumps
Crushers
Drilling Rigs
Engineering & Construction Machinery
Excavators
Gas Generation Equipment
Loaders
Mineral Separators
Mining Machinery
Mortar Spray Machines
Other Construction Machinery
Road Machinery
Stone Machinery
Tile Making Machinery
Truck Cranes
Baking Equipments
Beverage & Wine Machines
Cake machine
Donut machines
Fermenting Equipment
Fish Processing Machines
Flour & Rice Mills
Flour Mill
Food Sterilizers
Fruit & Vegetable Processing Machines
Fruit & Vegetable Processing Machines
Fryers
Ice Cream Machines
Juice Extractors
Meat Processing Machinery
Meat Slicers
Other Food Processing Machinery
Popcorn machine
Snack Machines
Vegetable Cutters
Vegetable Washing Equipments
Apparel & Textile Machinery
CNC industrial Machinery
Industrial Compressors & Parts
Industrial Robots
Industry Laser Equipment
Machine Tool Equipment
Manufacturing Machinery
Metal & Metallurgy Machinery
Paper Production Machinery
Plastic & Rubber Processing Machinery
Welding Equipment
Woodworking Machinery
Animal & Veterinary
Household Medical Devices
Medical Consumables
Professional Medical Devices
Testing Instrument
Bone Surgical Instruments
Burns Surgery Instruments
Clinical Analytical Instruments
Clinics Apparatuses
Dental Chair
Dental Consumables
Dental Equipments
Dental Handpiece
Diagnostic Apparatuses
Emergency & Clinics Apparatuses
General Assay & Diagnostic Apparatuses
Hospital Beds
Hospital Chairs
Hospital Trolley
Implants & Interventional Materials
Medical Cryogenic Equipments
Medical Imaging Equipment
Medical Optical Instruments
Medical Ultrasound Instruments
Medical X-ray Equipments
Obstetrics & Gynecology Equipments
Oral Therapy Equipments
Physical Therapy Equipment
Radiology Equipment & Accessories
Rehabilitation Equipment
Stethoscope
Surgical Instruments
Transfusion, Dialysis & Circulation Machines
Vacuum Suction Devices
Visual Acuity Examination Supplies
Featured Accessories
Mobile Phones
Phone Accessories
Screen Protector Machines
Tablets
Telecommunications
Broadcast Intercom Systems
Camera Modules
Communication Antennas
Corded Telephones
Development Boards, Kits
Enterprise Firewalls
Enterprise Switches
Fiber Optic Equipment
Fixed Wireless Terminals
Other Telecommunications Products
PBX
Signal conversion Boards
Telecom Parts
Wireless Infrastructure Equipment
Select a product option to continue.
Explore funding with Afrimart's partners. Subject to provider approval.



| Details | Technical documents (at the bottom) |




1) Protection of the grounding linc, the zero line must be reliable grounding and zero.
2) Conncction and requirements of main power supply: MD43Plus(MD43) EDM tool sharpening machincrequires three-phase five little system and 380 v power supply access, value error range is between +10% ~ 5%, the line voltage is not permitted on the mutation, and does not share power with otherhigh-power electrical equipment as far as possible, if you have the above situation, please ask users tobring thcir own stabilizer, otherwise the consequence is proud. In addition, the front end of the mainpower supply of the machine requires air switch and other protective measures.
3) Air circuit connection and requirements: the air circuit of MD43Plus(MD43) EDM tool grinding machinepartly requires 0.6mpa -- 0.8mpa of dry and pure compressed air to be connected, and the pressure of theair source treatment part on the machine tool is adjusted to be 0.4mpa.The air must be clean and frec of dust. No direct sunlight.
4)--There is no dust source such as grinder in the room, and the air is not polluted by abrasive particles.
--There should be no chemical corrosive vapor in the indoor air (not close to the chemical laboratory.surface heat treatment workshop,etc.).. --There should be no focus nearby. If any, the machine tool must be installed on the foundation withshockproof ditch.
--Excessive humidity (relative humidity between 40% and 60%) should be avoided. At 20°C, thehumidity should be less than 90%; at 40°C, the humidity of being no more than 50% is advisable.
--indoor temperature condition:
Guaranteed precision 20±3°CGuarantee the running 15~30°C
| 2) Conncction and requirements of main power supply | MD43Plus(MD43) EDM tool sharpening machincrequires three-phase five little system and 380 v power supply access, value error range is between +10% ~ 5%, the line voltage is not permitted on the mutation, and does not share power with otherhigh-power electrical equipment as far as possible, if you have the above situation, please ask users tobring thcir own stabilizer, otherwise the consequence is proud. In addition, the front end of the mainpower supply of the machine requires air switch and other protective measures. |
|---|---|
| 3) Air circuit connection and requirements | the air circuit of MD43Plus(MD43) EDM tool grinding machinepartly requires 0.6mpa -- 0.8mpa of dry and pure compressed air to be connected, and the pressure of theair source treatment part on the machine tool is adjusted to be 0.4mpa.The air must be clean and frec of dust. No direct sunlight. |
The machine requires a three-phase five-wire system and a 380V power supply. The voltage error range is between +10% and -5%. It is crucial not to share power with other high-power electrical equipment.
The machine requires a dry and pure compressed air supply of 0.6MPa to 0.8MPa. The air source treatment part should be adjusted to 0.4MPa.
Yes, the installation area must be free from dust, chemical corrosive vapors, and should have a humidity level between 40% and 60%. The temperature should be maintained between 15°C and 30°C for optimal operation.
The machine requires a reliable grounding connection for the grounding line and the zero line to ensure safety and proper function.
No, excessive humidity should be avoided. The relative humidity should be between 40% and 60%, with specific limits based on temperature.
Failure to meet the power supply conditions may lead to operational issues or damage to the machine. It is advisable to use a stabilizer if power conditions are not stable.
The ideal indoor temperature for guaranteed precision is 20±3°C, while the machine can operate effectively within the range of 15°C to 30°C.
Yes, the machine should be installed on a foundation with a shockproof ditch, especially if there are nearby focus sources that could cause vibrations.
No, the installation room should not have any dust sources such as grinders, as this can affect the machine's performance.
It is recommended to install an air switch and other protective measures at the front end of the main power supply to ensure safety.
The air must be clean and free of dust, and it should not be exposed to direct sunlight.
Operating the machine outside the recommended temperature range may affect its precision and performance. It is best to maintain the specified conditions.
If the air pressure is outside the required range of 0.6MPa to 0.8MPa, adjustments should be made to the air source treatment part to ensure proper operation.
Regular maintenance involves checking the air supply, ensuring proper grounding, and monitoring humidity and temperature levels in the installation area.
Training details may vary by supplier, so it is recommended to inquire directly with your vendor for training options and resources.