The model is HVS-100D and it has a 100 L sterilizing chamber with internal dimensions of φ440 × 650 mm.
Power rating is 3 kW and the unit requires AC 220 V, 50 Hz. Ensure an appropriate circuit and outlet are available.
Working pressure is 0.22 MPa (max 0.23 MPa) and working temperature is 134°C. Temperature stability (heat average) is ≤ ±1°C.
The timer ranges from 0–99 minutes or 0–99 hours 59 minutes, allowing you to run common steam sterilization cycles such as 121°C and 134°C programs with appropriate exposure times per your protocol.
It's suitable for sterilizing surgical instruments, fabrics, glassware, culture media and many laboratory tools. Always follow recommended packaging and loading practices for each item type.
Yes. The sterilizer features a fully stainless steel structure for durability and easy cleaning and corrosion resistance.
Built-in safety features include an automatic cool air discharge and steam release after the cycle, beep reminders, and auto shut-off after sterilization. Follow operating instructions and keep hands clear of the steam discharge to avoid burns.
The autoclave includes two stainless steel sterilizing baskets. Additional racks or trays may be available from the supplier.
Load instruments without overcrowding to allow steam circulation. Arrange hollow instruments open-end down and do not block the drain or steam ports. Use the supplied baskets and avoid stacking items tightly.
Yes, it can sterilize liquids, but use appropriate containers (loosely capped or vented), select the correct cycle and cooling/exhaust setting to avoid boilover or superheating. Follow laboratory protocols for liquid sterilization.
Perform daily chamber cleaning, empty and clean the drain, inspect and lubricate door seals as recommended, and check for leaks. Periodically run biological and chemical indicators for validation and arrange manufacturer-recommended service intervals.
Use chemical indicators (e.g., indicator tape/strips) in each load and regularly run biological indicators (spore tests) according to institutional or regulatory guidelines to confirm sterilization efficacy.
Check that the unit is plugged into a proper power source, ensure adequate water supply or reservoir level, confirm the door is fully sealed and locked, and inspect heating elements/fuses. Contact technical support or an authorized service technician if the issue persists.
Yes. Always allow the unit to depressurize and cool before opening the door, use protective gloves when handling hot loads, stand clear of steam discharge ports, and follow the user manual and local safety procedures.
Warranty and certification (e.g., CE, ISO) details are not listed in the basic product description. Contact the supplier or manufacturer for specific warranty terms, service contracts, and compliance/certification documentation.