The MS400 Visual Acuity Examination Apparatus is designed to provide accurate and reliable eye tests, making it ideal for clinics, hospitals, and medical professionals. This easy-to-use device helps measure vision clearly and efficiently, ensuring a smooth and precise examination process for both patients and healthcare providers.
Key Features
High Accuracy: The MS400 delivers precise visual acuity measurements, ensuring reliable results.
Electric Power Source: Powered by electricity with a USB recharge mode for convenience and efficiency.
Compact and Portable: Lightweight and easy to transport, making it ideal for use in various healthcare settings.
Long Shelf Life: The apparatus has a shelf life of 3 years, ensuring long-term reliability and durability.
CE Certification: The MS400 meets the CE standard, ensuring it meets European health and safety requirements.
Class II Instrument: Classified as a Class II device, ensuring it is safe for use in medical environments.
Visual Acuity Testing: Specifically designed to conduct visual acuity tests accurately.
Simple Operation: Easy for healthcare providers to use, with intuitive functions that speed up the examination process.
Quality Construction: Made from durable plastic, ensuring the device remains sturdy and reliable over time.
The MS400 Visual Acuity Examination Apparatus is an essential tool for accurate eye tests. With its reliable design and user-friendly features, it’s a perfect choice for medical professionals looking to provide top-quality care to their patients.
Product Info Gallery
Specification
Introduction MS400 Multiparameter Simulator is a portable device, features in small volume and light weight. It can simulate accurately 12-lead ECG, Respiration, Temperature, 2-channel IBP or 4-channel IBP. And it can be tested in where the monitor is used.
NOTE: TEMP and IBP Cable is necessary .not including package .
Functions
Simulate 35 kinds of arrhythmia (including Atrial, Ventricular, Premature Beat and Conduction Defects) and pacemaker waveforms (including Asynchronous, Demand Occ Sinus, Demand Freq Sinus, A/V Sequential, Non Capture, Non Function). Simulate four-channel IBP data. Simulate respiration signal with adjustable respiration rate, impedance and baseline impedance, and three kinds of apnea data. Simulate four kinds of temperature data. Simulate square wave, triangle wave, pulse wave and sine wave with adjustable frequency. Simulate standard ECG calibration, adult and pediatric ECG signal. ECG waveform complied with the standard of ANSI/AAMI EC13-2002, AHA, MIT ECG database, other ECG database and user-defined waveform data stored in TF card can be displayed by the simulator and exported to the equipments to be tested. Each waveform can be displayed by sliding the 3.5'' TFT touch screen, easy to operate. Power supply: rechargeable lithium battery or linear adapter, which reduces interference. Optional operation modes: keys and touch screen.
Performance 1)ECG Conventional All leads have the same voltage with the II-lead as the reference Amplitude 0.5,1.0,1.5 and 2.0mV ECG Rate 15,20,25,30,40,60,80,100,120,140,160, 180,200,220,240,260,280,300,320,340and 350 BPM ECG artifacts 50 and 60 Hz, muscle, baseline and breathing The elevation of the ST segment +0.8 to -0.8 mV, the step is 0.1 mV 2)Arrhythmia Atrial Atrial Fib(coarse), Atrial fib(fine), Atrial Flutter, Sinus Arrhythmia, Missed Beat, Atrial Tachycardia, Nodal Rhythm, Supraventricular Tachycardia Ventricular Vent Fib (coarse), Vent Fib (fine), PVCs 6/min, PVCs 12/min, PVCs 24/min, Frequent Multifocal, Bigeminy, Trigeminy, Paired PVCs, Run 5 PVCs, Run 11 PVCs, Vent Tachycardia, Asystole Premature Beat Atrial PAC, Nodal PNC, PVC1 LV Focus, PVC1 E LV Focus, R on T LV Focus,PVC2 RV Focus, PVC2 E RV Focus, R on T RV Focus, Multifocal PVC Conduction Defects First Degree Heart Block, Second Degree Heart Block, Third Degree Heart Block, Right Bundle Branch Block, Left Bundle Branch Block. 3)Four IBP Channels The default 00/00mmHg Dynamic IBP(unit: mmHg) Channel 1 Artery 120/80 Radial 120/80 Left Ventricle 120/00 Right Ventricle 25/00 Channel 2 Artery 120/80 Radial 120/80 Left Ventricle 120/00 Right Atrium(CVP) 15/10 Right Ventricle 25/00 Pulmonary Artery 25/10 Pulmonary Wedge 10/2 Left Atrium 4/4 Channel 3 Artery 120/80 Radial 120/80 Left Ventricle 120/00 Right Atrium(CVP) 15/10 Right Ventricle 25/00 Pulmonary Artery 25/10 Pulmonary Wedge 10/2 Left Atrium 14/4 Channel 4: Auto Swan-Ganz (every 15 seconds) RA(CVP), RV, PA, PAW (Pulmonary Wedge) Man Swan-Ganz press ENTER key to change every time Static-Pressure Levels Channel 1 0, 80, 160, 240, 320 and 400mmHg Channel 2 0, 50, 100, 150, 200 and 250mmHg Channel 3 0, 20, 40, 60, 80 and 100mmHg Channel 4 P4 tracks the static pressure levels of P3 4)Respiration Respiration Rate 0 (Apnea), 15, 20, 30, 40, 60, 80, 100, 120 and 150 R/MIN Impedance 0.2, 0.5, 1.0 and 3.0 Ω Baseline impedance 500, 1000, 1500, 2000Ω Apnea 12 s, 22 s, 32 s 5)Temperature Four temperature 0℃(32°F), 24℃( 75°F), 37℃(98.6°F), 40℃(104°F)Accessories Standard accessories 9V/1A(CE) power adapter, an User manual, a packaging box, a plastic packaging. conversion software)
Shipping Timeframes: All orders are processed within 2-5 business days (excluding weekends and holidays). After your order has been processed, the estimated delivery time is before 31 Jan, 2025, depending on customs, Please note that due to high demand, some items may experience longer shipping times, which will be communicated at order confirmation email.
Order Processing Time: Please allow 2-5 business days for us to process your order before it is shipped . Orders placed after 16:00 on Fridays, or during weekends and public holidays, will begin processing on the next business day. Processing times may be extended during peak seasons or sales events.
Manufacturing Time: Some products needs manufacturing time, the manufacturing process will take approximately 10-30 business days depending on the product. This timeframe may vary depending on the complexity of the product and current demand. but this will be communicated with you during order confirmation.
Returns and Exchanges: We offer a 30-day return policy for most items. If you are not completely satisfied with your purchase, you may return it within 30 days of receipt for a refund or exchange. Items must be unused, in their original packaging, and accompanied by proof of purchase. Return shipping costs are the responsibility of the customer, unless the item was damaged or defective upon arrival.
0
0 Overall Rating
5
0%
0
4
0%
0
3
0%
0
2
0%
0
1
0%
0
Review this product
For you to write a review, you need to login first
Afrimart Online stands as Africa's foremost e-commerce hub, featuring an expansive array of product categories spanning electronics, machinery, toys, furniture, and more. Committed to excellence, our platform delivers swift and streamlined logistics and customs clearance solutions, offering a comprehensive one-stop service for cross-border imports.
Leveraging over three decades of international trade expertise, we ensure a seamless and hassle-free importing experience, providing top-tier products at competitive prices to meet the diverse needs of African consumers.
At Afrimart, we strive to process all orders promptly. Once the payment has been successfully cleared into our account, your order will be processed within 2 to 5 business days. Please note that this processing time excludes weekends and public holidays.
Following the processing of your order, the estimated delivery lead time ranges between 35 to 60 days. However, please be aware that this timeframe is subject to variations due to potential delays in shipping and customs clearance. While we aim to adhere to the original delivery schedule, unforeseen circumstances may occasionally extend the delivery window beyond the anticipated 35 to 60 days.
In the event of high demand or other factors leading to longer shipping times for certain items, we will communicate any expected delays during the initial order confirmation. We appreciate your understanding and patience as we work to ensure your order arrives as swiftly as possible.