B21, China Town Mall, Midrand
Welcome to Afrimart OnlineWrap new offers/gift every single day on Weekends.New Coupon Code: Fast024
Something you love is now on sale! Buy Now !
Blood Gas And Electrolyte Analyzer

0 Customer Reviews

  • Shipping Timeframes: All orders are processed within 2-5 business days (excluding weekends and holidays). After your order has been processed, the estimated delivery time is before 25 Dec, 2025, depending on customs, Please note that due to high demand, some items may experience longer shipping times, which will be communicated at order confirmation email.
  • Order Processing Time: Please allow 2-5 business days for us to process your order before it is shipped . Orders placed after 16:00 on Fridays, or during weekends and public holidays, will begin processing on the next business day. Processing times may be extended during peak seasons or sales events.
  • Manufacturing Time: Some products needs manufacturing time, the manufacturing process will take approximately 10-30 business days depending on the product. This timeframe may vary depending on the complexity of the product and current demand. but this will be communicated with you during order confirmation.
  • Returns and Exchanges: We offer a 30-day return policy for most items. If you are not completely satisfied with your purchase, you may return it within 30 days of receipt for a refund or exchange. Items must be unused, in their original packaging, and accompanied by proof of purchase. Return shipping costs are the responsibility of the customer, unless the item was damaged or defective upon arrival.
1. What is the Blood Gas And Electrolyte Analyzer (NYSTE-SG1)?

The NYSTE-SG1 is a handheld blood gas and electrolyte analyzer that combines microfluidic and micro-biosensing technologies to deliver point-of-care blood gas and electrolyte testing.

2. Which sample types can be tested?

The analyzer accepts whole blood, serum, and plasma samples.

3. How much sample is required?

Typical sample volume is 100 µL (roughly 2–3 drops of whole blood).

4. How many steps are required to run a test at the patient side?

Testing can be performed in three simple steps at the patient's side using a single-use test card.

5. How long does it take to get results?

Accurate results are delivered in approximately 4 minutes to support rapid clinical decision-making.

6. What are the test cards and how do they work?

The system uses single-use multi-parameter test cards. Each card contains a unique combination of biosensors and is identified via a QR code to load the correct assay parameters.

7. Is the device truly handheld and portable?

Yes. The unit is lightweight (about 600 g) and includes a built-in 3.7V, 5000 mAh battery for portable, point-of-care, field, or exam-room use.

8. What are the display and printing options?

The analyzer features a 4.3-inch IPS touchscreen and a built-in thermal printer for on-the-spot hardcopy results.

9. How is the device powered and charged?

It operates from a 5V/2A supply and uses an internal rechargeable battery. The device charges via a USB Type-C connector.

10. What environmental conditions are required for operation?

Recommended operating temperature is 5–32 °C, relative humidity ≤85%, and barometric pressure between 86.0 kPa and 106.0 kPa.

11. How is data exported or integrated with hospital systems?

The analyzer provides a Type-C connector for data transfer and printouts via the built-in printer. For EMR/LIS integration options, consult the vendor for available interfaces and protocols.

12. What routine maintenance and quality control are required?

Regular maintenance includes cleaning the sample port, proper storage and handling of single-use cards, running external quality controls per laboratory policy, and following the manufacturer's calibration and maintenance schedule.

13. How should used test cards and biological waste be disposed of?

Used test cards and residual blood are biohazardous and must be discarded according to local clinical waste regulations and institutional infection-control procedures.

14. Does the device require calibration or consumables?

Yes. The system uses single-use test cards (consumables) and requires periodic quality controls and calibration as specified by the manufacturer and local regulatory requirements.

15. Where can I get regulatory, warranty, and ordering information?

Contact the manufacturer or authorized distributor for details on regulatory status, warranty coverage, authorized service, and to place orders.

0

0 Overall Rating
  • 5
    0%
    0
  • 4
    0%
    0
  • 3
    0%
    0
  • 2
    0%
    0
  • 1
    0%
    0

Review this product

For you to write a review, you need to login first

Login

Latest Order Arrivals

Discover our latest orders

12 Heads Embroidery Machine
12 Heads Embroidery Machine
Dewatering Pump Machine
Dewatering Pump Machine
Order Collection
Order Collection
Portable Water Drilling Rig
Portable Water Drilling Rig
Order Usefully Collected
Order Usefully Collected
Batch of Orders
Batch of Orders
Agriculture Processing Machines
Agriculture Processing Machines
Meat Grinder Machine
Meat Grinder Machine
Water Pump Equipment
Water Pump Equipment
Packaging Machine and accessories
Packaging Machine and accessories
Fabrics Manufacturing Equipment
Fabrics Manufacturing Equipment
Mining Equipments
Mining Equipments
Food Processing Machine
Food Processing Machine
Batch of Orders
Batch of Orders
Batch of Orders
Batch of Orders
Latest Orders Labelled
Latest Orders Labelled
wheel alignment machines
wheel alignment machines
new arrivals
new arrivals
Pre Orders Offloading
Pre Orders Offloading
Latest Arrivals
Latest Arrivals
Latest Arrivals
Latest Arrivals
Latest Arrivals
Latest Arrivals

Related Products

Recently Viewed Products