The YSOT-ZXY01 is an electric, automatic pneumatic tourniquet system (Class II medical device) designed to provide controlled limb occlusion with adjustable pressure and timing for surgical and clinical procedures.
Pressure range: 3 kPa to 100 kPa; Time range: 1 minute to 600 minutes; Input power consumption: 12 VA; Power supply: 110–220 V, 50/60 Hz; Weight: 2 kg. The unit ships with 4 cuffs and 1 air hose.
The YSOT-ZXY01 is CE certified and classified as a Class II medical instrument. Always follow local regulatory and facility requirements when using the device.
Use the front-panel controls to select the target pressure within the 3–100 kPa range and set the timing from 1 to 600 minutes. Refer to the supplied user manual for step‑by‑step instructions and recommended clinical settings.
The system includes 4 cuffs. Choose cuff width and size based on limb circumference and procedure type; wider cuffs require lower pressure for the same occlusive effect. Follow the cuff sizing guidance in the user manual or institutional protocols.
Yes. The unit is lightweight (approximately 2 kg), making it easy to move within clinical areas. It requires AC mains power (110–220 V) to operate—there is no built‑in rechargeable battery.
The system provides automatic pressure control to maintain precise, consistent inflation. It also includes safety controls and settings to limit maximum pressure and duration; consult the user manual for detailed alarm and lockout behavior.
Disconnect and deflate cuffs before cleaning. Wipe external surfaces and cuffs with a hospital‑approved disinfectant compatible with the materials. Do not immerse the main unit or expose it to sterilization conditions unless the manual explicitly permits it. Follow facility infection control policies and the device manual.
Regular functional checks before each use are recommended. For accuracy assurance, have the system inspected and calibrated by authorized service personnel at intervals defined by local regulations or at least annually.
Confirm mains power is present and that the power cord is securely connected. Verify the correct voltage (110–220 V) and check any external fuses or circuit breakers. If the unit still does not power on, contact Ysenmed service or your supplier.
Check cuff placement and ensure the cuff and air hose are intact and connected properly. Inspect for leaks, kinks, or damaged tubing. If problems persist, stop use and contact authorized service for inspection and repair.
Use only as directed by qualified medical personnel. Exercise caution or avoid use in patients with severe peripheral vascular disease, uncontrolled infection at the application site, or other conditions where limb occlusion is contraindicated. Always follow clinical guidelines and the device manual.
Shelf life is listed as 1 year. Store the device and accessories in a clean, dry environment at room temperature, away from direct sunlight and corrosive substances. Keep accessories in their original packaging until use.
The standard package includes 4 cuffs and 1 air hose. Additional or replacement cuffs and hoses are typically available from the manufacturer or authorized distributors—contact your supplier for compatible spare parts.
Contact your Ysenmed distributor or the authorized service center listed on the product documentation for warranty claims, maintenance, repairs, and user training. Keep purchase and serial number information available when contacting support.