B21, China Town Mall, Midrand
Welcome to Afrimart OnlineWrap new offers/gift every single day on Weekends.New Coupon Code: Fast024
Something you love is now on sale! Buy Now !
16 Zones 2-3-4 Wired Conventional Fire Alarm System Control Panel

0 Customer Reviews

  • Shipping Timeframes: All orders are processed within 2-5 business days (excluding weekends and holidays). After your order has been processed, the estimated delivery time is before 03 Feb, 2026, depending on customs, Please note that due to high demand, some items may experience longer shipping times, which will be communicated at order confirmation email.
  • Order Processing Time: Please allow 2-5 business days for us to process your order before it is shipped . Orders placed after 16:00 on Fridays, or during weekends and public holidays, will begin processing on the next business day. Processing times may be extended during peak seasons or sales events.
  • Manufacturing Time: Some products needs manufacturing time, the manufacturing process will take approximately 10-30 business days depending on the product. This timeframe may vary depending on the complexity of the product and current demand. but this will be communicated with you during order confirmation.
  • Returns and Exchanges: We offer a 30-day return policy for most items. If you are not completely satisfied with your purchase, you may return it within 30 days of receipt for a refund or exchange. Items must be unused, in their original packaging, and accompanied by proof of purchase. Return shipping costs are the responsibility of the customer, unless the item was damaged or defective upon arrival.
1. What is the maximum number of zones supported by the SR-P01 Series fire alarm control panel?

The SR-P01 Series supports up to sixteen zones, with models available for 4, 8, and 16 zones.

2. What type of circuits does the SR-P01 Series use?

The SR-P01 Series uses Class B (Style B) Initiating Device Circuits (IDCs), which are compatible with two-wire smoke detectors and normally-open contact devices.

3. Can I connect security alarm devices to this control panel?

Yes, the control panel has two supervisory inputs with DC12V output, making it ideal for connecting security alarm devices.

4. What is the total system power of the SR-P01 Series?

The total DC24V system power for the SR-P01 Series is 3.0 amps.

5. Does the control panel allow for programming of alarm outputs?

Yes, the control panel allows for programming the notification appliance circuits (NACs) to be silenceable or non-silenceable.

6. What type of batteries can be used with the SR-P01 Series?

The SR-P01 Series is designed for use with sealed lead-acid batteries, with a maximum capacity of 18AH. Two 10AH batteries can be housed in the cabinet.

7. Is there a communication port available on the control panel?

Yes, there is an optional RS485 communication port available for the SR-P01 Series.

8. Can I disable or enable zones individually?

Yes, the control panel allows for individual control to disable or enable each zone (IDC) as needed.

9. What is the maximum current per notification appliance circuit (NAC)?

The maximum current per NAC is 1.25 amps.

10. How is the power output for smoke detectors configured?

The SR-P01 Series includes both resettable four-wire smoke detector power output and non-resettable power output options.

11. What are the alarm relay ratings for this control panel?

The integral Form-A Alarm, Trouble, and Supervisory relays are rated at 2.0 amps @ 30 VDC (resistive) and 2.0 amps @ 30 VAC (resistive).

12. What input power requirements does the SR-P01 Series have?

The control panel requires AC power of 220VAC, 50 Hz.

13. Can the system be operated in automatic or manual mode?

Yes, the SR-P01 Series can be programmed to operate in either automatic or manual mode.

14. What happens in the event of a zone input short circuit?

The zone input short circuit can be set to trigger either an 'Alarm' or 'Fault' mode, depending on your configuration.

15. How can I order the correct model for my needs?

You can order the SR-P01 Series models based on the number of zones you require: SR-P01-4 for 4 zones, SR-P01-8 for 8 zones, and SR-P01-16 for 16 zones.

0

0 Overall Rating
  • 5
    0%
    0
  • 4
    0%
    0
  • 3
    0%
    0
  • 2
    0%
    0
  • 1
    0%
    0

Review this product

For you to write a review, you need to login first

Login

Latest Order Arrivals

Discover our latest orders

12 Heads Embroidery Machine
12 Heads Embroidery Machine
Dewatering Pump Machine
Dewatering Pump Machine
Order Collection
Order Collection
Portable Water Drilling Rig
Portable Water Drilling Rig
Order Usefully Collected
Order Usefully Collected
Batch of Orders
Batch of Orders
Agriculture Processing Machines
Agriculture Processing Machines
Meat Grinder Machine
Meat Grinder Machine
Water Pump Equipment
Water Pump Equipment
Packaging Machine and accessories
Packaging Machine and accessories
Fabrics Manufacturing Equipment
Fabrics Manufacturing Equipment
Mining Equipments
Mining Equipments
Food Processing Machine
Food Processing Machine
Batch of Orders
Batch of Orders
Batch of Orders
Batch of Orders
Latest Orders Labelled
Latest Orders Labelled
wheel alignment machines
wheel alignment machines
new arrivals
new arrivals
Pre Orders Offloading
Pre Orders Offloading
Latest Arrivals
Latest Arrivals
Latest Arrivals
Latest Arrivals
Latest Arrivals
Latest Arrivals

Related Products

Recently Viewed Products