This is a built-in LED curing light designed to connect directly to a dental chair. It provides high-intensity blue LED light to cure dental materials such as composite resins and light-activated adhesives, assist in orthodontic procedures, and improve treatment efficiency and patient comfort.
The product is designed for direct connection to a dental chair via the chair's accessory/interface. Connection details (mounting style, connector type, or required adapter) can vary by chair model — verify compatibility with your chair model or consult the supplier for required adapters.
The curing light is mains-powered (electricity). Voltage and plug type may vary by region — confirm electrical specifications with the seller or product documentation before installation.
The unit uses blue LED light in the polymerization spectrum (typically around 430–490 nm). Exact irradiance (mW/cm²) and peak wavelength are not listed here — check the product datasheet or ask the manufacturer for precise technical values.
Curing time depends on the composite resin, layer thickness and the light intensity. Typical curing times range from about 10 to 40 seconds per increment. Follow the resin manufacturer's recommendations and verify with the unit's intensity for optimal results.
Yes — the product is listed as a Class II instrument and carries CE quality certification, indicating it meets relevant European safety and performance standards. Always follow local regulations and clinic protocols when installing and using medical devices.
The product specification lists dimensions of 26 x 25 x 26 cm and a single gross weight of 0.135 kg. Because packaging and included accessories may affect size/weight, confirm exact package contents and measurements with the supplier prior to purchase.
Regular maintenance typically includes wiping external surfaces with an appropriate disinfectant, inspecting cables and connectors for wear, and ensuring optical surfaces are clean and undamaged. Follow the manufacturer's maintenance schedule and cleaning instructions to avoid damage.
Not all parts are autoclavable. Use protective barriers (e.g., disposable sheaths) on surfaces that contact the patient, and follow the manufacturer's guidance for any removable components. Do not autoclave parts unless explicitly stated as autoclavable by the manufacturer.
The listed shelf life is 1 year. This typically refers to storage life prior to installation or use. For best performance, follow storage recommendations and check product condition prior to deployment if stored for extended periods.
Yes — online technical support is indicated as available. Contact details and support hours should be provided by the seller or manufacturer. Keep your purchase information and serial number handy when requesting support.
Wear appropriate protective eyewear for yourself and the patient while activating the light. Avoid direct prolonged exposure to the beam. Use barriers to prevent cross-contamination and adhere to standard infection-control protocols.
A specific warranty period is not listed in the product description. Warranty terms vary by supplier — check the seller’s warranty policy and included coverage (parts, labor, service) before purchasing.
Check power supply and connections to the dental chair, ensure any on/off switches are set correctly, inspect cables for damage, and verify any fuses or circuit breakers. If basic checks fail, contact the manufacturer or technical support for further diagnostics.
Provide your dental chair make/model and any accessory interface details to the supplier. Ask for a compatibility confirmation, required adapters, electrical requirements, and installation instructions. If possible, request documentation or a trial fit prior to purchase.
Discover our latest orders